KQD-11系列計(jì)數(shù)型電火花檢測(cè)儀(電火花檢漏儀)檢驗(yàn)報(bào)告模板如下:
一、檢驗(yàn)儀器名稱、型號(hào)(Name and Model of Detector)
產(chǎn)品名稱Description |
電火花防腐層檢漏儀Electric spark detector |
規(guī)格型號(hào)Specification |
|
出廠編號(hào)Factory No. |
|
出廠日期Production Date |
|
制造單位Manufacturer |
|
二、檢驗(yàn)環(huán)境條件及地點(diǎn) Condition and Location of Testing
溫度:19.0℃ 相對(duì)濕度:51%(Temperature: 19.0℃ Relative humidity: 51%)
地點(diǎn):
三、電火花檢測(cè)儀檢驗(yàn)結(jié)果 (Test Result)
1.外觀檢測(cè):符合要求;(Appearance testing: comply with requirements.)
2.絕緣電阻:合格;(Insulation resistance: up to standard.)
3.示值誤差:(單位KV)(Indication error (Unit: KV))
輸出電壓Output voltage |
測(cè)量電壓Actual voltage |
2 |
2.1 |
5 |
5.3 |
10 |
10.8 |
15 |
14.9 |
20 |
20.6 |
30 |
30.9 |
4.擊穿報(bào)警次數(shù) Breakdown alarm frequency
設(shè)定次數(shù)Setting times |
報(bào)警次數(shù)Alarm times |
30 |
30 |
5. 檢驗(yàn)結(jié)論:符合產(chǎn)品技術(shù)要求
(Test conclusion: comply with technical requirements of produc)t.
檢驗(yàn)單位(Testing company:)
核驗(yàn)(Verification:)
測(cè)試(Testing:)
建議有效期一年,本報(bào)告適用于全量程電火花檢測(cè)儀檢驗(yàn), It is recommended that the period of validity shall be one (1) year.,相關(guān)電火花檢漏儀儀器:
http://www.mnareadyshop.com/